TM 9-2320-289-20
10-36. PERSONNEL HEATER, FUEL FILTER, AND BLOWER REPLACEMENT (M1010).
This task covers:
a.
Removal
c.
Heater Bleeding
b. Installation
INITIAL SETUP:
Equipment Condition
Materials/Parts
Both battery negative cables disconnected.
C o t t e r p in
(See paragraph 4-38)
Exhaust gasket
Filter element
Filter seal
Fuel oil (Item 17, Appendix C)
Pipe sealant (Item 43, Appendix C)
Plastic tube (Item 49, Appendix C)
Personnel Required
General Safety Instructions
MOS 63B (2)
DO NOT perform this procedure near
fire, flames, or sparks.
a.
REMOVAL
WARNING
Diesel fuel is flammable, DO NOT perform this procedure near fire,
flames, or sparks. A fire extinguisher must be on hand in work area.
Failure to follow this warning
personnel.
If removing personnel
may result in serious injury or death to
NOTE
heater (1), perform steps 1-6.
If removing fuel filter assembly, perform steps
If removing blower motor, perform steps 1-6,
Clean all old sealant from all pipe threads.
1, 2, and 7.
and 8.
1.
Remove outside access panel from right rear ambulance body.
NOTE
Use suitable container to catch fuel when disconnecting hose (5) and
disassembling fuel filter assembly.
2.
Disconnect hose (5) from personnel heater. Loosen fitting (3) and remove hose from fuel filter
body (2) .
3.
Loosen clamp (10) and disconnect flex hose (11) from adapter (8). Remove 4 screws (7) and
adapter.
10-130