TM 9-2320-289-2010-36. PERSONNEL HEATER, FUEL FILTER, AND BLOWER REPLACEMENT (M1010)(Con’t).c .HEATER BLEEDINGWARNINGDiesel fuel is flammable. DO NOT performflames, or sparks. A fire extinguisher mustFailure to follow this warning may result inpersonnel.NOTEthis procedure near fire,be on hand in work area.serious injury or death toUse suitable container to catch fuel from hose (5) and bleed port (31).1.Connect both battery negative cables. (See paragraph 4-38)2.Hold personnel heater switch in “START” position. Continue operation until a clean, steadyflow of fuel is obtained, then shut off personnel heater. Connect hose (5) to personnel heater(1).3.Connect wiringh a r n e s s ( 9 ) topersonnel heater (1).4.Remove personnel heater (1) cover.Connect plastic tube to bleed port(31). Open bleed port. Hold cabheater switch in “START” position.Continue operation until a clean,steady flow of fuel is obtained, thenshut off cab heater. Close bleed portand remove plastic tube.5.Install personnel heater (1) cover.6.Install outside access panel on rightrear ambulance body.TA5003510-135/(10-136 blank)