TM 9-2320-289-2010-35. PERSONNEL HEATER CONTROL BOX REPLACEMENT (M1010) (Con’t).3.Disconnect wiring harness (15) from control box (11). Disconnect control box wire assemblyfrom blower motor lead.4.Loosen clamp (8) and disconnect duct hose (9) from weldment (7). Loosen clamp (17) anddisconnect flex hose (16) from weldment. Remove 4 screws (13) from adapter (14). Removeadapter and flex hose assembly from personnel heater (12).5.Using 90 degree angle drill, remove 8 pop rivets (10). Remove control box (11) and clean oldsealant from mating surfaces. Discard pop rivets.b. INSTALLATION 1.Apply RTV sealant to inside flange of control box (11). Install control box with 8 new pop rivets(10).2.Install adapter (14) and flex hose (16) assembly on personnel heater (12) with 4 screws (13).Connect flex hose to weldment (7) and tighten clamp (17). Connect duct hose (9) toweldment and tighten clamp (8).3.Connect control box (11) wire assembly to blower motor lead. Connect wiring harness (15) tocontrol box.TA5002910-128