TM 9-2320-289-20
10-35. PERSONNEL HEATER CONTROL BOX REPLACEMENT (M1010) (Cont).
4,
Connect 2 cables (2) to vent door
control levers (6). lnstall 2 clamps (3)
on cables and heater base (1) with 2
screws (5). Install 2 pushnuts (4).
5.
Install outside access panel on right rear ambulance body.
FOLLOW-ON TASKS:
Connect both battery negative cables. (See paragraph 4-38)
Check operation of heater and cables.
TA50030