TM 9-2320-289-20
10-36. PERSONNEL HEATER, FUEL FILTER, AND BLOWER REPLACEMENT (M1010)
(Cont).
5.
With personnel heater (1) securely in
heater base (4) opening, compress
seal (12) about 0.5 in. (1.2 cm).
Loosely install 2 clamps (6) around
personnel heater.
6.
Install adapter (8) with 4 screws (7) if
removed. Connect flex hose (11) to
adapter and tighten clamp (10).
7.
Connect hose (5) to fuel filter body (2) and tighten fitting (3).
8.
Tighten clamps (6) securely.
TA50034
10-134