TM 9-2320-280-34
15-3. 6,000 LB. ELECTRIC WINCH REPAIR (Cont'd)
19.
lnstall leads (11), (12), and (13) on terminals (18), (15), and (14) with three nuts (10).
20.
Apply pipe sealant to threads of vent tube fitting (17).
21.
Install vent tube fitting (17).
22.
Install control (6) on motor (9) with clamp (16).
23.
Connect control connector (7) to motor connector (8).
NOTE
Lead 6C must be positioned to align with opening in cover.
24.
Install lead 6C (5) on control (6) with nut (4).
25.
Install ground wire (9.1) and lead 7C (1) on motor (9) with capscrew (3).
3
1
9.1
4
5
6
9
8
7
15-14