15-3. 6,000 LB. ELECTRIC WINCH REPAIR (Cont'd)
15.
Assemble gasket (8) and coupling (19) on motor (21) and install on drum support (15), ensuring to
align reference marks.
16.
Install motor (21) on drum support (15) with ten socket head screws (20). Using hex head driver,
tighten screws (20) to 35 lb-in. (4 Nm).
NOTE
If motor or control have been pre-coated with sealing compound,
remove compound from between motor case and control mounting gear
contact area. Failure to do so may cause improper grounding of
control.
17.
Install clamp (18) on motor (21).
18.
Install control (17) on motor (21).
Change 2
15-13