4-3.
ALTERNATOR TESTING AND REPAIR (M1010) (Cont).
3.
Remove 4 screws (14), Iockwashers (13), washers (12), brush cover (11), and brush holder
gasket (15), Discard Iockwashers and gasket.
4.
Remove brush holder (9). Remove 2 brushes (10) and O ring (16) from brush holder.
Discard O ring.
NOTE
Perform step 5 only if brush holder adapter (17) or connector are
damaged. Leads connected to brush holder adapter will have to be cut
from locking terminals to remove brush holder adapter.
5.
Remove 2 screws (8) and pull out brush holder adapter (17). Tag and disconnect 2 leads from
brush holder adapter, and remove brush holder adapter.
6..
Remove bushing (7) if damaged.
TA50786