TM 9-2320-289-34
4-2.
ALTERNATOR TESTING AND REPAIR (ALL EXCEPT M1010) (Cont).
6. Install end frame bearing (31 ) to end
frame (1) by supporting inner face of
end frame with a socket and pressing
bearing in from outside to inside until
flush with end frame.
7. Install capacitor (8), rectifier bridge-to-regulator jumper wire (10), wire retainer, and screw
(24) .
8. Position rectifier bridge fiber insulator in end frame (1) hole where screw (22) is to be installed.
Position negative (-) terminal plastic insulator in end frame hole where negative (-) terminal
(18) is to be installed.
TA50783
4-11