TM 9-2320-289-20
4-21.
FLOODLIGHT AND GAS-PARTICULATE FILTER UNIT (GPFU) SWITCHES
REPLACEMENT (M1010).
This task covers:
a. Removal
b. Installation
INITIAL SETUP:
Equipment Condition
Instrument cluster plate removed. (See paragraph 4-7)
1.
Remove screw
(3) and switch
required.
(7) and retainer (6) from back of instrument panel (1). Remove switch cover
plate (2). Remove 1 or both floodlight switches (5) and GPFU switch (4) as
1.
Install 1 or both floodlight switches (5) and GPFU switch (4) on switch cover (3) if removed.
Position switch plate (2) and switch cover on instrument panel (1). Install retainer (6) on back
of instrument panel and on back of switch plate with screw (7).
FOLLOW-ON TASKS:
Install instrument cluster plate. (See paragraph 4-7)
Check operation of floodlight and gas-particulate filter unit.
TA49883
4-44