TM 9-2320-289-34
F-1 .
GAS-PARTICULATE FILTER UNIT (GPFU) INSTALLATION (M1010) (Cont).
16.
Install flex hose (7) with hose wall
clamp (19) and ground lead from
gas-particulate filter unit (6) under it,
to upper left front corner, using screw
removed in step 1.
NOTE
Ensure that vinyl hose (17) is cut
as required.
17.
connect two 2 in. (51 mm) clear
vinyl hoses (17) to 2 tees (2) with 2
clamps.
Slide 2 additional clamps
onto 2 hoses for use in mounting 2
canisters (10).
18.
Position 2 band clamps (16) on left
side of existing brackets on front wall
for mounting of 2 canisters (10).
TA50185
F-5