TM 9-2320-289-34
F-1 .
GAS-PARTICULATE FILTER UNIT (GPFU) INSTALLATION (M1010) (Cont).
2.
Connect 2 brass adapters (1) and
ends of 2 tees (2). Connect 2 tees
with attached adapters to nipple (4).
Tighten so that 2 side openings (3) in
tees are facing same direction.
3.
Connect 2 aluminum adapters (1) to
side openings (3) of 2 tees (2),
4 .
Position tee and nipple assembly on
left side wall,
level with existing
bracket on front wall.
5 .
Install 2 tee clamps (5) around tee
and nipple assembly where 2 brass
adapters (1) connect to 2 tees (2).
Ensure that sides (3) of tees are both
pointed away from outside wall.
Secure 2 tee clamps with screws and
Iockwashers.
TA50182
F - 2