TM 9-2320-289-34
F-1 .
GAS-PARTICULATE FILTER UNIT (GPFU) INSTALLATION (M1010) (Cont).
6.
Connect 1 end of 2 ft. (0,61 m) flex hose (7) to top of tee and nipple assembly and tighten
with hose clamp. Connect 1 end of another 2 ft. (0. 61 m) fIex hose (15) to lower end of tee
and nipple assembly and tighten with hose clamp,
7.
Install gas-particulate filter unit frame assembly (8) to upper left front wall of patient
compartment, above existing brackets, with bolts and Iockwashers.
8.
Connect ground lead to screw on backside of gas-particulate filter unit (6), Install
gas-particulate filter unit into gas-particulate filter unit frame assembly (8) with ground lead
threaded up from behind.
Ensure that any plugs found in
removed before installing brass
heater is already plugged, leave
NOTE
patient heater (12)
adapters (1). If top
plug in place.
inlets or outlets are
inlet (13) of patient
9.
Connect 2 brass adapters (1) to top and side outlets (11) of patient heater (12). Connect 1
brass adapter to side inlet (14) of heater.
TA50183
F - 3