T M 9 - 2 3 2 0 - 2 8 9 - 34
4-5.
STARTER TESTING AND REPAIR (Cont).
CAUTION
Ensure that field housing (3) assembly is carefully positioned on drive gear
housing (1). Failure to follow this caution may result in damage to
brushes.
8 .
Position field housing (3) assembly on
drive gear housing (1) ensuring that
alinement pin engages drive gear
housing hole. install commutator end
frame (6) on field housing with bolt
(5) and stud (4).
9 .
Apply sealing compound to solenoid
(2) flange where it contacts field
housing (3). install plunger spring
(10) in solenoid. Rotate solenoid 90
degrees and install on drive gear
housing (1) with 2 new lockwashers
and screws (9).
10.
Carefully insulate field coil connector
(7) from solenoid (2) terminal.
Connect one 24 volt battery lead
from 500 amp test stand to solenoid
terminal and other battery lead to
starter frame.
TA50804
4 - 3 6