T M 9 - 2 3 2 0 - 2 8 9 - 344-5.STARTER TESTING AND REPAIR (Con’t).CAUTIONEnsure that field housing (3) assembly is carefully positioned on drive gearhousing (1). Failure to follow this caution may result in damage tobrushes.8 .Position field housing (3) assembly ondrive gear housing (1) ensuring thatalinement pin engages drive gearhousing hole. install commutator endframe (6) on field housing with bolt(5) and stud (4).9 .Apply sealing compound to solenoid(2) flange where it contacts fieldhousing (3). install plunger spring(10) in solenoid. Rotate solenoid 90degrees and install on drive gearhousing (1) with 2 new lockwashersand screws (9).10.Carefully insulate field coil connector(7) from solenoid (2) terminal.Connect one 24 volt battery leadfrom 500 amp test stand to solenoidterminal and other battery lead tostarter frame.TA508044 - 3 6