TM 9-2320-289-34
4-5.
STARTER TESTING AND REPAIR (Cont).
11.
12,
13.
Connect jumper lead momentarily
from solenoid (2) terminal to starter
frame. This will move pinion (42) into
cranking position until battery leads
are disconnected.
Check clearance between pinion (42)
and collar (22). If clearance is not
0.010-0.140 in.
(0.25-3.56 mm),
disconnect test stand battery leads,
disassemble starter, and check for
incorrect installation.
Replace any
worn components and retest,
Disconnect test stand battery leads.
Remove insulation between field coil
connector
(7) and solenoid (2)
terminal, Install screw (8) on field coil
connector,
TA50805
4-37