TM 9-2320-289-34
4-5.
STARTER TESTING AND REPAIR (Cont).
NOTE
Ensure that position of field coil assembly (38) is noted for assembly.
12.
Remove 8 pole shoe screws (36) and 4 pole shoes (37). Remove field coil assembly (38) from
field housing (3). Remove alinement pin (39) if damaged.
c .
CLEANING AND INSPECTION
I
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Always wear
protective goggles and gloves and use only in a well-ventilated area.
Avoid contact with skin, eyes, and clothes and DO NOT breathe vapors.
DO NOT use near open flame or excessive heat. The solvents flash
point is 100°F-138°F (38°C-59°C). If you become dizzy while using
cleaning solvent, immediately get fresh air and medical help. If solvent
contacts eyes, immediately wash your eyes with water and get medical
aid.
Compressed air used for cleaning purposes should never exceed 30 psi
(207 kPa). Use only effective chip guarding and personnel protective
equipment (goggles/shield, gloves, etc.). Failure to follow this warning
may result in serious injury to personnel.
TA50799