TM 9-2320-289-34
4-6.
INSTRUMENT PANEL WIRING HARNESS AND EXTENSION REPLACEMENT.
This task covers:
a. Removal
b. Installation
INITIAL SETUP:
Equipment Condition
Materials /Parts
Instrument cluster removed,
l
Grease (Item 36, Appendix B)
(See TM 9-2320-289-20)
l
Antiseize tape (Item 65, Appendix B)
Voltmeter relay, generator 2 relay, and starter
relay removed, (See TM 9-2320-289-20)
Manual References
Transfer case bezel, plate, boot, and control
l TM 9-2320-289-20
lever housing removed.
(See TM 9-2320-289-20)
Instrument panel padding removed.
(See TM 9-2320-289-20)
a.
REMOVAL
NOTE
If removing all except M1010 instrument panel wiring harness, perform
steps 1 through 7, 9 through 12, and 14.
If removing M1010 instrument panel wiring harness, perform
steps 1-14.
If removing instrument panel extension wiring harness, perform steps 13
and 15.
Voltmeter lamp connector (8), WATER-IN-FUEL light connector (11 ),
WAIT light connector (12), and instrument cluster connector (13)
were disconnected when instrument cluster was removed.
Ensure that all leads and connectors are tagged for installation.
1.
At underside of steering column (1),
disconnect
wiper/washer
switch
connector (4) from wiper/washer
switch (3). Unplug wiper/washer
switch from bracket (2).
TA50806
4 - 3 8
Change 2