4-5.
STARTER TESTING AND REPAIR (Cont).
7 .
8 .
9 .
Check continuity between field housing (3) and brushes (34) at grounded brush holders (35).
Check continuity between field coil connector (7) and brushes at insulated brush holders (31).
If there is no continuity in step 7, check connections at brushes (34) and brush holders (31 and
35). Replace any damaged components. If connections are good, and no components appear
damaged, replace field coil assembly (38).
Check for continuity between brushes (34) at grounded brush holders (35) and brushes at
insulated brush holders (31). If there is continuity, replace field coil assembly (38).
NOTE
Ensure that all leads are tagged for installation,
10.
Remove brush support pin (28). Separate brush spring (30), grounded brush holder (35), and
insulated brush holder (31 ) from brush support (29).
11.
if removing field coil assembly (38) or brushes (34), remove 2 screws (33) at insulated brush
holders (31) and disconnect field coil assembly leads (32), Remove screw and disconnect
field coil assembly lead from field coil connector (7). Remove field coil connector and
grommet if damaged.
TA50798