TM 9-2320-289-344-5.STARTER TESTING AND REPAIR (Con’t).7 .8 .9 .Check continuity between field housing (3) and brushes (34) at grounded brush holders (35).Check continuity between field coil connector (7) and brushes at insulated brush holders (31).If there is no continuity in step 7, check connections at brushes (34) and brush holders (31 and35). Replace any damaged components. If connections are good, and no components appeardamaged, replace field coil assembly (38).Check for continuity between brushes (34) at grounded brush holders (35) and brushes atinsulated brush holders (31). If there is continuity, replace field coil assembly (38).NOTEEnsure that all leads are tagged for installation,10.Remove brush support pin (28). Separate brush spring (30), grounded brush holder (35), andinsulated brush holder (31 ) from brush support (29).11.if removing field coil assembly (38) or brushes (34), remove 2 screws (33) at insulated brushholders (31) and disconnect field coil assembly leads (32), Remove screw and disconnectfield coil assembly lead from field coil connector (7). Remove field coil connector andgrommet if damaged.TA507984-30