TM 9-2320-289-20
10-31. GAS-PARTICULATE FILTER MAINTENANCE (M1010) (Cont).
4.
Install manifold (5) with 4 screws (6) and new Iockwashers (7).
5.
Install filter assembly (1) to filter
mount with clip (2).
6.
Connect ground wire to back of filter
housing (10).
7.
Connect 2 hoses (4) to manifold (5)
and tighten clamps (3).
FOLLOW-ON TASKS:
Connect both battery negative cables. (See paragraph 4-38)
Check GPFU for proper operation. (See TM 9-2320-289-10)
TA50022