TM 9-2320-289-2010-31. GAS-PARTICULATE FILTER MAINTENANCE (Ml 010).This task covers:a. Removalc. Installationb. Cleaning and InspectionINITIAL SETUP:Equipment ConditionMaterials/Parts• Both battery negative cables disconnected.• Four Iockwashers(See paragraph 4-38)• Dry cleaning solvent(Item 15, Appendix C)Manual References• FM 3-5• TM 10-277• TM 9-2320-289-10General Safety Instructions• If filter has been used in a Nuclear, Biological, or Chemical (NBC) environment specialprecautions must be taken.• Dry cleaning solvent is flammable and must not be used near open flame. Use only in awell-ventilated area.WARNING• Only authorized and trained personnel are to remove and servicegas-particulate filters that have been used in an NBC environment. Seelocal SOP for disposing contaminated filters. Failure to follow thiswarning may result in serious illness or death to personnel.• Special protective clothing (See TM 10-277) must be used and specialsafety measures and decontamination procedures (See FM 3-5) mustbe followed when replacing contaminated filters. Failure to follow thiswarning may result in serious illness or death to personnel.10-113