TM 9-2320-289-2010-31. GAS-PARTICULATE FILTER MAINTENANCE (M1010) (Con’t).1.2.3.NOTEIf the following conditions exist,replace gas canisters (12) andgas-particulate filter (9):physical darnage or water immersion; filterbecomes clogged, resulting in insufficient air flow. Replace ALL gascanisters and gas-particulate filters after operating in an NBC environment.Loosen 2 clamps (3) and disconnecthoses (4) from filter manifold (5).Disconnect ground wire from back offilter housing (10).Lift clip (2) and remove filterassembly (1).4.Remove 4 screws (6) and Iockwashers (7), and remove manifold (5). Discard Iockwashers.NOTEIf gas-particulate filter (9) is likely to be reused and no arrow is present,mark an arrow on its side showing direction of airflow.5.Remove gas-particulate filter (9).TA5001910-114