TM 9-2320-289-20
10-22. ENDGATE WINDOW AND WINDOW REGULATOR REPLACEMENT (M1009)
(Cont).
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Always wear
protective goggles and gloves and use only in a well-ventilated area. Avoid
contact with skin, eyes, and clothes and DO NOT breathe vapors. DO NOT
use near open flame or excessive heat, The solvents flash point is
100°F-138°F (38°C-59°C). If you become dizzy while using cleaning
solvent, immediately get fresh air and medical help. If solvent contacts
eyes, immediately wash your eyes with water and get medical aid.
5.
Carefully remove sash (15), filler (16), and window (17) assembly. Apply dry cleaning solvent
to filler along sash on both sides of window glass. When filler softens, remove window and filler
from sash. Remove old filler from sash and window. Discard filler.
6.
Remove 2 nuts (27), base (19), and handle assembly (28).
7.
Remove bezel (26) and gasket (20) from base (19). Remove 2 screws (29), Separate arm of
handle assembly (28) from base and remove pin (30).
8.
Remove clip (25) and clutch (24). Remove retainer (23), spring washer (22), and ring (21),
Remove pawl (32) and spring (31), and remove lock unit (18).
TA49995
10-80