TM 9-2320-289-20
10-8.
DOOR AND VENT WINDOW MAINTENANCE.
This task covers:
a. Removal
c. Assembly
b. Disassembly
d. Installation
INITIAL SETUP:
Equipment Condition
Materials/Parts
Window glass lowered to full down position.
Door panel removed.
(See paragraph 10-7)
Sharp edges of door frame covered.
One rivet
One vent window filler or one door
window filler
Adhesive (Item 2, Appendix C)
Dry cleaning solvent
(Item 15, Appendix C)
Tape (Item 48, Appendix C)
Too/s/Test Equipment
General Safety Instructions
Screwdriver bit set, J-29843
Dry cleaning solvent is flammable and
must not be used near open flame.
Use only in a well-ventilated area.
a.
REMOVAL
NOTE
If replacing vent window, perform DISASSEMBLY steps 2 and 3.
If removing vent window assembly (17), perform steps 1-4.
1.
Remove screw (5) and slide up cover (3). Remove bolt (4), From inside of door, remove bolt
(1) and reinforcement (6). Remove spacer (2).
2.
Remove 2 screws (10) and spacers
(11). Remove screw (12).
3.
Remove screw (16). Loosen screw
(9). Peel top of window glass run (14)
from door (13), Peel edge of window
glass run from vent window assembly
(17). Pull vent window assembly and
window glass run from door, and
remove vent window assembly from
window glass run.
4.
Remove screw (9), retaining nut (7),
and bumper (8) if damaged.
TA49946
10-22