TM 9-2320-289-2010-8.DOOR AND VENT WINDOW MAINTENANCE.This task covers:a. Removalc. Assemblyb. Disassemblyd. InstallationINITIAL SETUP:Equipment ConditionMaterials/PartsWindow glass lowered to full down position.Door panel removed.(See paragraph 10-7)Sharp edges of door frame covered.One rivetOne vent window filler or one doorwindow fillerAdhesive (Item 2, Appendix C)Dry cleaning solvent(Item 15, Appendix C)Tape (Item 48, Appendix C)Too/s/Test EquipmentGeneral Safety Instructions• Screwdriver bit set, J-29843• Dry cleaning solvent is flammable andmust not be used near open flame.Use only in a well-ventilated area.a.REMOVALNOTE• If replacing vent window, perform DISASSEMBLY steps 2 and 3.• If removing vent window assembly (17), perform steps 1-4.1.Remove screw (5) and slide up cover (3). Remove bolt (4), From inside of door, remove bolt(1) and reinforcement (6). Remove spacer (2).2.Remove 2 screws (10) and spacers(11). Remove screw (12).3.Remove screw (16). Loosen screw(9). Peel top of window glass run (14)from door (13), Peel edge of windowglass run from vent window assembly(17). Pull vent window assembly andwindow glass run from door, andremove vent window assembly fromwindow glass run.4.Remove screw (9), retaining nut (7),and bumper (8) if damaged.TA4994610-22