TM 9-2320-280-34
15-4. 9,000 LB. ELECTRIC WINCH REPAIR (Cont'd)
NOTE
If motor or control have been pre-coated with sealing compound, remove
compound from between motor case and control mounting gear contact
area. Failure to do so may cause improper grounding of control.
25.
Install two clamps (24) on motor (21).
26.
Install control (22) on motor (21) and tighten two clamps (24).
27.
Connect three leads (23) to terminals (27) with nuts (26) and slide rubber boots (25) over nuts (26).
28.
Apply pipe sealant to threads of set screw (28) and install on motor (21).
29.
Connect control connector (35) to motor connector (36).
30.
Connect lead 6 (34) to control (22) with nut (33).
31.
Connect lead 7 (29) to motor (21) with lockwasher (30) and capscrew (31).
31
32
29
21
36
33
34
22
Change 2
15-23
35