TM 9-2320-289-34
5-7.
TRANSMISSION CONTROL VALVE ASSEMBLY AND DETENT SOLENOID
MAINTENANCE (Cont).
8.
Remove retaining pin (43), detent bore plug (37), detent valve (38), detent regulator valve
(39), detent regulator valve spring (41), and detent spacer (40).
9.
Remove retaining pin (42), 1-2 bore plug (46), 1-2 accumulator valve (45), and 1-2 primary
accumulator spring (44).
c .
CLEANING AND INSPECTION
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Always wear
protective goggles and gloves and use only. in a well-ventilated area. Avoid
contact with skin, eyes, and clothes and DO NOT breathe vapors. DO NOT
use near open flame or excessive heat. The solvents flash point is
100°F-138°F (38°C-59°C). if you become dizzy while using cleaning
solvent, immediately get fresh air and medical help. If solvent contacts
eyes, immediately wash your eyes with water and get medical aid.
TA50219
5-31