TM 9-2320-289-34
5-7.
TRANSMISSION CONTROL VALVE ASSEMBLY AND DETENT SOLENOID
MAINTENANCE (Cont).
2 .
3.
4 .
Install 1-2 primary accumulator spring (44) and 1-2 accumulator valve (45), stem end out, into
bore. Install 1-2 bore plug (46) into bore with hole end facing out. Install grooved retaining pin
(42) with grooves to outside.
Install detent spacer (40) inside detent regulator valve spring (41). Install both ensuring that
detent regulator valve spring seats in bottom of bore.
Install detent regulator valve (39), stem end out, and detent valve (38), small land first, into
bore. Install detent bore plug (37), hole end out. Install retaining pin (43).
5.
6.
7.
8.
9.
Install 3-2 shift valve (33). Install 3-2 spacer (32) inside 3-2 valve spring (31) and install both
inside bore,
Compress 3-2 valve spring (31) and install 3-2 bore plug (30), hole end out, Install retaining pin
(34) .
Install 2-3 intermediate spring (28) in open end of 2-3 shift valve (29). Install both in bore
ensuring that valve seats in bottom of bore.
Install 2-3 modulator valve (25), hole end first. into 2-3 modulator bushing (27) and install both
in bore.
I n s t a l l 2 - 3 s h i f t v a l v e s p r i n g ( 2 6 ) i n h o l e i n 2 - 3 s h i f t v a l v e
spring and install retaining pin (35).
TA50221
5-34