1 0 .
Install 1-2 shift valve (20), stem end out, ensuring that valve seats in bottom of bore.
1 1 .
Install spring (22) into small end of 1-2 regulator valve (23). Install assembled spring and valve
into 1-2 modulator bushing (24). Install 1-2 detent valve (21), hole end first, into 1-2 modulator
bushing.
12.
Install 1-2 modulator bushing (24) assembly into bore and compress enough to install retaining
pin (36).
13.
Install manual valve (7).
TA50222