TM 9-2320-289-34
4-3.
ALTERNATOR TESTING AND REPAIR (M1010) (Cont).
NOTE
If either rectifier was replaced,
leads (22) will have to be spliced
together
with
terminal
loops
before installing positive rectifier
(28) and negative rectifier (20).
10.
11.
Install 2 lower housing bushings (27)
on screws (23). Install output terminal
bushings (19) and upper housing
bushings (18) on output terminal
screws (5). Install rectifier assembly
in slipring end housing (1) and install
2 nuts (4) on output terminal screws,
Connect 2 leads to positive rectifier
(28) and 1 lead to negative rectifier
(20), and install 3 screws (21).
Connect rectifier leads (22) to AC
terminal studs (45).
TA50791