TM 9-2320-289-20
5-2.1.
TRANSMISSION VACUUM LINES REPLACEMENT.
This task covers:
a.
Removal
b. Installation
INITIAL SETUP:
Equipment Conditions
Both battery negative
Air cleaner removed.
cables disconnected. (See paragraph 4-38)
(See paragraph 3-9)
1.
Disconnect hose (8) from vacuum modulator assembly (7).
2.
Remove clip (10) from fill tube assembly (9) and vacuum pipe (5).
3.
Remove 2 nuts (1) from valve cover studs (3).
4.
Remove 3 nuts securing crankcase depression regulator valve (CDRV) assembly (4) mounting
bracket to valve cover and intake manifold. Move CDRV assembly free of vacuum pipe (5).
TA701834
5-5.0
Change 2