TM 9-2320-289-205-2.TRANSMISSION FILTER ASSEMBLY MAINTENANCE (Con’t).1.CleanWARNINGDry cleaning solvent P-D-680 is toxicprotective goggles and gloves and useand flammable. Alwavs wearonly in a well-ventilated area.Avoid contact with skin, eyes, and clothes and DO NOT breathe vapors.DO NOT use near open flame or excessive heat. The solvent’s flashpoint is 100°F-138°F (38°C-59°C). If you become dizzy while usingcleaning solvent, immediately get fresh air and medical help. If solventcontacts eyes, immediately wash your eyes with water and get medicalaid.Compressed air used for cleaning purposes will not exceed 30 psi(207 kPa). Use only effective chip guarding and personnel protectiveequipment (goggles/shield, gloves). Failure to follow this warning mayresult in serious injury to personnel.old RTV sealant or oldtransmission oil pan gasket (11) fromlip of transmission oil pan (2) andfrom transmission housing with drycleaning solvent. Thoroughly dry withcompressed air.NOTEWhencleaningmagnet (12),ensure that all metal filings areremoved.2.Clean transmission oil pan (2) andmagnet (12) with dry cleaningsolvent.Thoroughlydrywithcompressed air.1.Install screen grommet (13) into neckof transmission oil filter assembly (8).NOTENote markings on intake pipe (14)and ensure that it is installedproperly.One end is marked“FILTER” and other end is marked“CASE.“2.Install new seal (7) and intake pipe(14) intotransmissionoil filterassembly (9).5-4
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business