TM 9-2320-289-20
4-32.
SURGICAL LAMP REPLACEMENT (M1010).
This task covers:
a. Removal
b. Installation
INITIAL SETUP:
Equipment Condition
Both battery negative cables disconnected. (See paragraph 4-38)
1.
Remove lens cover (4) by carefully
pulling retaining flanges out of fixture
(1) tracks, 1 side at a time.
NOTE
Fluorescent tube (2) is spring-
Ioaded at rear socket (3).
2.
Push fluorescent tube (2) against rear
socket (3) to free fluorescent tube
from front fixture socket, and remove
fluorescent tube.
b.
INSTALLATION
1.
Insert 1 end of fluorescent tube (2)
into rear socket (3). While pushing
fluorescent tube against rear socket,
guide fluorescent tube contacts into
front fixture socket. Ensure that
fluorescent tube is securely in place
before releasing.
2.
Install lens cover (4) by carefully
pushing retaining flanges into fixture
(1) tracks, 1 side at a time.
FOLLOW-ON TASKS:
Connect both battery negative cables. (See paragraph 4-38)
Check operation of surgical light.
TA49897
4-62