TM 9-2320-289-20
4-13.
BODY FUSES AND RELAYS REPLACEMENT (M1010) (Cont).
3.
Connect service outlet negative lead (13) with nut (14).
4.
Install jumper cable (8) on positive electrical stud (22) and circuit breaker (10). Connect outlet
positive lead (20). Install 2 nuts (9).
5.
Install 24 v air conditioner relay (17) with 2 screws (16). Connect relay plug (18) to 24 v air
conditioner relay. Repeat as required for gas-particulate filter unit relays (3 and 4), 12 v air
conditioner relay (6), and blackout light relay (7).
6.
Install 25 amp air conditioner fuse (26), 30 amp heater and blackout light fuse (25), and 30
amp heater fuse (27) on lower fuse block (24) if removed.
7.
Install 20 amp in-line air conditioner fuse (19) if removed.
8.
Install 15 amp receptacle fuses (28) on upper fuse block (23) if removed.
9.
Install cover (1) on relay panel (5) with 4 screws (2).
FOLLOW-ON TASKS:
Connect both battery negative cables. (See paragraph 4-38)
Check operation of applicable circuit.
TA49873
4-34