TM 9-2320-289-34
5-5.
GOVERNOR ASSEMBLY MAINTENANCE.
This task covers:
a. Removal
d. Assembly
b. Disassembly
e. Installation
c. Cleaning and Inspection
INITIAL SETUP:
Equipment Condition
Materials/Parts
Transfer case in 2H.
l
l
Tools/Test Equipment
l
l Torque wrench
l
General Safety Instructions
l Dry cleaning solvent is flammable and must not be
well-ventilated area.
One gasket
Two pins
Dry cleaning solvent
(Item 23, Appendix B)
Hydraulic fluid (Item 40,
used near open flame.
Compressed air used for cleaning purposes should never exceed 30 psi (207
Appendix B)
Use only in a
kPa),
a.
REMOVAL
NOTE
A suitable container should be used to catch hydraulic fluid when
removing governor cover (2) and governor assembly (4).
1.
Remove 4 bolts (1) and governor cover (2) from transmission case (5). Remove gasket (3)
and discard. Remove governor assembly (4) from bore of transmission,
TA50210
5-20