TM 9-2320-289-34
3-45.
FUEL INJECTOR PUMP CALIBRATION (Cont).
(e)
(f)
Place throttle to low idle position
and aline zero-degree mark on
protractor (25) with center of rib
on rocker lever (21).
Rotate throttle lever (17) to wide
open throttle position. Reading
on protractor (25) should be
73-82 degrees.
e .
CALIBRATION]
1 .
Set rpm to 1500, with throttle lever
(17) in wide open throttle position.
Disconnect positive test lead (14)
from -- shutoff
solenoid
terminal.
Maximum flowmeter reading should
be 4.0 cc. Connect positive test lead
to shutoff solenoid terminal.
3-169