TM 9-2320-289-34
3-38.
FUEL INJECTOR PUMP SHUTOFF SOLENOID AND COLD ADVANCE
SOLENOID REPLACEMENT (Cont).
c.
INSTALLATION
NOTE
If installing governor cover (2), perform steps 3-6.
1.
Install cold advance solenoid (13) in
governor cover (2). Install new seal
(6) and connector (5), ensuring that
connector is centered on plunger
(14), Install insulating washer (7),
washer
(8),
nut
(10),
2
new
Iockwashers (9), terminal insulator
(12), and new locknut (11 ).
2.
Install shutoff solenoid (24) in
governor cover (2) with 2 insulating
washers (21 ), 2 washers (20), 2 nuts
(19), new Iockwasher (25), 4 new
Iockwashers (18), terminal ground
strap (16), terminal insulator (17),
and 2 new locknuts (15).
NOTE
Movement from linkage (23) or
plunger (14) when cold advance
solenoid (13) or shutoff solenoid
(24) are energized indicates
proper operation,
3.
Connect negative lead of 12 volt
power source to governor cover (2)
and positive lead to locknut (11) to
check operation of cold advance
solenoid (13).
Repeat for shutoff
solenoid (24) by connecting positive
lead to either locknut (15). Replace
cold advance solenoid or shutoff
solenoid if not operating properly.
TA50724
3-127