TM 9-2320-289-2010-21. ENDGATE MAINTENANCE (M1009) (Con’t).7.Remove clip (42) and disconnect handle rod (43) from handle (40). Remove 2 screws (41)and handle.8.Remove 3 screws (39) and control assembly (28). Disconnect handle rod (43) from controlassembly.NOTEStop (34) is factory-installed with flanged nut and washer instead of nut(36) and Iockwasher (35). Use nut and Iockwasher for installation.9.Remove spring (38). Remove 2 screws (33) and lockout rod (32). Remove nut (36),Iockwasher (35), bolt (37), and stop (34). Discard Iockwasher.TA4998910-74