TM 9-2320-289-204-9.VOLTMETER,V O L T M E T E R R E L A Y,A N D G E N E R A T O R 2 R E L A YREPLACEMENT.This task covers:a. Removalb. InstallationINITIAL SETUP:Equipment ConditionInstrument cluster plate removed (if removing voltmeter or door ajar housing). (Seeparagraph 4-7)NOTEIf removing voltmeter (6), perform step 1.If removing door ajar housing (3) on M1010 only, perform step 2.Generator 2 relay (7) is on all except M1010. If removing generator 2relay or voltmeter relay (8), perform step 3.1.Remove 2 nuts (5) and washers (4),and retaining bracket (1). Removevoltmeter (6) from instrument clusterplate (2).2.Remove door ajar housing (3) frominstrument cluster plate (2).3.Reach up under bracket (10) besidesteering column (9) and disconnectlead (12) from generator 2 relay (7)or lead (11) from voltmeter relay (8).Removegenerator 2 relay orvoltmeter relay.NOTEgenerator 2 relay (7) or voltmeter relay (8) for all exceptIf installingM1010, perform step 1.If installing door ajar housing (3) on M1010 only, perform step 1.If installing voltmeter (6), perform step 2.1.Install generator 2 relay (7) or voltmeter relay (8) on bracket (10) beside steering column (9).Connect lead (12) to generator 2 relay or lead (11) to voltmeter relay.2.Install door ajar housing (3) on instrument cluster plate (2).TA498674-26