TM 9-2320-280-34
22-9.3. LEFT REAR FLOOR PA NEL REPAIR (Cont'd )
g. Metal Strip C and Insert Panel Assembly
1.
Position metal strip C (2), with arrow facing up and toward left, on insert panel (1). Align reference
lines (3) with edges of insert panel (1).
2.
Using metal strip C (2) as a template, locate, mark, and drill ten 0.187-in. diameter holes through
insert panel (1).
3.
Apply approximately 0.125-in. thickness of adhesive sealant to shaded surface of insert panel (1)
and metal strip C (2).
4.
Position metal strip C (2) on insert panel (1) and install with ten rivets (4).
5.
Remove any adhesive residue and clean edges on metal strip C (2) and insert panel (1).
22-16.38
Change 1