TM 9-2320-280-34
6-5. 200 AMPERE ALTERNATOR (12338796-1) TESTING AND REPAIR (Cont'd)
c. Static Testing
NOTE
Refer to disassembly for component removal, if necessary.
1.
Perform Stator Test.
(a) Remove six nuts and phase leads from diodes in front housing.
(b) Set ohmmeter to XI scale and zero ohmmeter.
(c) Connect ohmmeter leads between each successive pair of stator phase leads "P1" - "P2", "P2" -
"P3", and "P1" - "P3". Ohmmeter should read less than 1 ohm. If ohmmeter reads infinity (),
(d) Set ohmmeter to X10 scale and zero ohmmeter.
(e) Connect ohmmeter leads between each phase lead, "P1", "P2", and "P3" and the ground
terminal on outside of front housing. Ohmmeter should read infinity (). If ohmmeter reads
(f) Repeat step (e) to check phase lead "P4", "P5", and "P6".
2.
Perform Field Coil Test.
(a) Remove two nuts and field coil leads (F+, F-) from diodes in front housing.
(b) Set ohmmeter to XI scale and zero ohmmeter.
(c) Connect ohmmeter leads to the two field leads and measure the resistance. Ohmmeter should
read less than 3 ohms. If ohmmeter reads more than 3 ohms, the field coil is open, replace
(d) Set ohmmeter to X10K scale and zero ohmmeter.
(e) Connect one ohmmeter lead to a field lead and the other to the ground stud on the front
housing. Ohmmeter should read infinity (). If ohmmeter reads less than 100K ohms, the field
3.
Perform Positive Diode Test.
(a) Set ohmmeter to X100 scale and zero ohmmeter.
(b) Connect one ohmmeter lead to the "B+" output stud and the other lead to each of the six diode
terminals "S". Ohmmeter should read nearly alike for all six, either less than 600 ohms or
infinity (). Reverse ohmmeter leads, ohmmeter should read nearly alike for all six but opposite
the first set of readings. If readings are not opposite, the diode rectifier assembly is BAD,
4.
Perform Negative Diode Test.
(a) Set ohmmeter to X100 scale and zero ohmmeter.
(b) Connect one ohmmeter lead to the ground terminal and the other lead to each of the six diode
terminals "S". Ohmmeter should read nearly alike for all six, either less than 600 ohms or
infinity (). Reverse ohmmeter leads, ohmmeter should read nearly alike for all six but opposite
the first set of readings. If readings are not opposite, the diode rectifier assembly is BAD,
d. Cleaning
6-42