TM 9-2320-289-345-22.TRANSFER CASE MAINTENANCE (M1028A1 AND M1031) (Con’t).b. DISASSEMBLY WARNINGDry cleaning solvent P-D-680 is toxic and flammable. Always wear protectivegoggles and gloves and use only in a well-ventilated area. Avoid contact withskin, eyes, and clothes and DO NOT breathe vapors. DO NOT use near openflame or excessive heat. The solvent’s flash point is 100°F-138°F(38°C-590C).If you become dizzy while using cleaning solvent,immediately get fresh air and medical help. If solvent contacts eyes,immediately wash your eyes with water and get medical aid.NOTEAll bearing assemblies should be tagged as they are removed.1.If fill plug (33) and drainplug (32) are installed, remove.2.Remove 4-wheel drive indicator light switch (17), gasket, spring, and ball. Discard gasket,4.Remove seal (35) from extension (27), Discard seal,TA701858 5-164Change 2