TM 9-2320-289-204-39.BATTERY AND RELATED COMPONENTS MAINTENANCE (Con’t).1.Remove 2 nuts (2) and batteryretainer (1) from hook bolts (4).2.Check charge indicators (5) on top ofbatteries.3.if indicator (5) shows a green dot,battery is okay.4.5.6.7.8.9.WARNINGDO NOT charge, test, or slave start battery when built-in hydrometershows clear or light yellow. An explosion may occur causing serious injuryor death to personnel.If indicator (5) appears dark with no green dot, recharge and test battery.TM 9-6140-200-14)If indicator (5) shows a clear or light yellow dot, replace battery.Remove battery caps and check electrolyte level. If level is low, notify your supervisor.Check specific gravity. (See TM 9-6140-200-14)Visually check for corrosion and damage.(SeeIf corroded, clean battery posts and cable connections with wire brush and soda solution, andlightly coat battery posts with grease. If damaged, replace as required.TA499084-80