TM 9-2320-289-20
3-9.
AIR CLEANER AND SEAL REPLACEMENT.
This task covers:
a.
Removal
b. Installation
CAUTION
When servicing air cleaner assembly (6), place a screen or a clean rag
over air intake opening to guard against objects falling
follow this caution may result in equipment damage.
1.
Remove 2 nuts (2), 2 washers (1),
and lid (3) of air cleaner assembly
(6) .
2.
Remove filter element (4), polywrap
band (5), and air cleaner assembly
(6) .
3.
Remove air cleaner seal (7) and
discard if damaged.
4.
Clean polywrap band (5) if required.
(See TM 9-2320-289-10)
b.
INSTALLATION
NOTE
Remove screen or
intake opening.
rag from air
1.
If removed, install air cleaner seal (7)
over intake manifold inlet (9).
2.
Install air cleaner assembly (6) on air
cleaner seal (7).
3.
Install filter element (4) and polywrap
band (5) inside air cleaner assembly
(6) .
4.
Install lid (3) of air cleaner assembly
(6) with studs (8) on intake manifold
inside. Failure to
(9) fitted through holes in lid.
TA49778