TM 9-2320-280-34
22-9.4. RIGHT FRONT FLOOR PANEL REPAIR (C nt'd )
o
d. Metal Strip Aand Insert Panel Assembly
1.
Position metal strip A (2), with arrow facing up and toward left, on insert panel (1). Align reference
line (3) with edge of metal strip A (2) and reference lines (5) with edge of insert panel (1).
2.
Using metal strip A (2) as a template, locate, mark, and drill ten 0.187-in. diameter holes through
insert panel (1). Remove metal strip A (2).
3.
Apply approximately 0.125-in. thickness of adhesive sealant to shaded surface of insert panel (1)
and metal strip A (2).
4.
Position metal strip A (2) on insert panel (1) and install with ten rivets (4).
5.
Remove any adhesive residue and clean edges of metal strip A (2) and insert panel (1).
22-16.58
Change 1