TM 9-2320-280-34
3-22. ENGINE REMOVAL (6.2 L AND 6.5 L [DETUNED]) (Cont'd)
NOTE
Disconnects for the 100 amp and 200 amp Neihoff regulators are
basically the same. Differences are shown in the illustration.
Perform steps 64 through 77 for vehicles equipped with Neihoff
200 amp alternator only.
Prior to removal, tag leads for installation.
64.
Disconnect regulator plug (13) from voltage regulator (12).
65.
Slide back rubber boot (4) and remove nut (3), lead 5A (2), and washer (1) from red (energize)
terminal (19).
66.
Slide back rubber boot (5) and remove nut (6), lead 2A (7), and washer (8) from yellow (AC)
terminal (9).
67.
Remove two screws (18), spring tension washers (17), and washers (16) from voltage regulator (12)
and alternator (15). Discard spring tension washers (17).
68.
Remove capscrew (10), lockwasher (11), spacer (14), and voltage regulator (12) from alternator (15).
Discard lockwasher (11).
3-60
Change 2