TM 9-2320-289-347-3.POWER BOOSTER REPAIR (Con’t).WARNINGAccumulator (2) contains compressed gas. DO NOT apply heat toaccumulator. DO NOT attempt to repair an inoperative accumulator,always replace an inoperative accumulator with a new one. Drill a 1/16 in.(1.6 mm) hole through end of accumulator can opposite “O” ring (8) todispose of an inoperative accumulator. Failure to follow this warning mayresult in serious injury or death to personnel,NOTEIt may be necessary to rotate accumulator retaining ring (7) so that it ispositioned in line with hole (10) in housing (9).2 .Insert a punch into hole (10) in housing (9) and remove accumulator retaining ring (7). Slowlyback off “C” clamp (1) until tension on accumulator (2) is released. Remove accumulatorremover, accumulator, and “O” ring (8), Discard “O” ring.TA503777-7