TM 9-2320-289-34
7-3.
POWER BOOSTER REPAIR (Cont).
WARNING
Accumulator (2) contains compressed gas. DO NOT apply heat to
accumulator. DO NOT attempt to repair an inoperative accumulator,
always replace an inoperative accumulator with a new one. Drill a 1/16 in.
(1.6 mm) hole through end of accumulator can opposite O ring (8) to
dispose of an inoperative accumulator. Failure to follow this warning may
result in serious injury or death to personnel,
NOTE
It may be necessary to rotate accumulator retaining ring (7) so that it is
positioned in line with hole (10) in housing (9).
2 .
Insert a punch into hole (10) in housing (9) and remove accumulator retaining ring (7). Slowly
back off C clamp (1) until tension on accumulator (2) is released. Remove accumulator
remover, accumulator, and O ring (8), Discard O ring.
TA50377
7-7