TM 9-2320-289-20Table 2-3. Mechanical Troubleshooting (Con’t)MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONAMBULANCE PERSONNEL HEATER33. SMOKY HEATER EXHAUST AFTER 5 MINUTES CONTINUOUS OPERATIONWARNINGBefore checking for restrictions, allow exhaust pipe to cool. Failure tofollow this warning will result in serious burns.Step 1.Check air inlet or exhaust outlet for restrictions.Remove any restrictions.If there are no restrictions, replace heater, (See paragraph 10-36)34. STARTS BUT SHUTS OFF COMPLETELYStep 1.Ensure that truck fuel tank is at leastStep 2.Inspect air passages for restrictions.Clear restrictions. Allow system¼ full. Add fuel if low.to cool before retesting.WARNINGDiesel fuel is flammable. When disconnecting fuel lines to test fuel flow,direct fuel spray away from source of ignition. A fire extinguisher must beon hand in work area. Failure to follow this warning may result in seriousinjury or death to personnel.Step 3.Remove side panel from heater compartment. Disconnect fuel line from inlet sideof heater. Place suitable container under inlet line. Check for fuel flow to heaterwhile holding run-start switch in the “START” position.If fuel flow is evident, replace heater (SeeIf fuel flow is not evident, perform step 4.Step 4.Check for restrictions in heater inlet fuel line.If line is restricted, clear restriction.paragraph 10-36)2-48