24.
Install control bracket (9) and ground terminal (12) on heater body (15) with two screws (4).
25.
Install control bracket (9) on heater body (15) with six screws (10).
26.
Connect fuel line (14) to fuel control valve fitting (11) with line nut (13).
27.
Connect two igniter leads (3) to ground terminal (12) and circuit board (5).
28.
Install five leads (1) on flame detector switch (20) with five assembled-washer screws (2).
29.
Install leads 30 (19) and 9 (18) on overheat switch (16) with two nuts (17).
30.
Group leads together with four tiedown straps (8).
31.
Install guard (6) on control bracket (9) with two dzus fasteners (7).
14-68