TM 9-2320-289-34
3-48.
WATER PUMP REPLACEMENT (Cont).
3.
4.
5.
6.
WARNING
Avoid skin contact with anaerobic sealing compound. Immediately wash
off skin if contact is made. Failure to follow this warning may result in
injury to personnel.
2. Apply anaerobic sealing compound
(25) to crankcase cover (18) in
pattern shown.
Apply pipe sealant to threads of bolts (17). Apply pipe sealant to oil filler tube studs (16) and
stud (23) on portion of threads installed on crankcase cover (18).
Install water pump (8) and water pump plate (5) on crankcase cover (18) with long bolt (22),
long screw (21 ), 2 studs (13), 2 screws (24), stud (23), 4 bolts (17), and 2 oil filler tube studs
(16). Tighten bolts (17) and stud (23) to 35 Ib.-ft. (47 N.m). Tighten all other bolts, studs, and
screws to 20 Ib.-ft. (27 Nom).
Connect radiator outlet hose (1 O) to water pump (8) and tighten clamp (9). Connect
thermostat bypass hose (6) to water pump and tighten clamp (7).
Install grommet (11 ) on water pump plate (5). Install oil filter tube (4) on water pump plate with
2 nuts (1 2). Connect crankcase depression regulator valve hose to oil filler tube and tighten
clamp.
TA50773
3-182